Search results for "electromagnetic [current]"

showing 10 items of 1008 documents

Radiation Defects in LiBaF3 Perovskites

2000

We investigated the electron paramagnetic resonance (EPR), recombination afterglow, thermostimulated luminescence (TSL) and absorption of LiBaF3 perovskites crystals X-irradiated at 80 K The self-trapped hole centre VK(F2-) oriented along the [110] axis and electron F type (FA) centres are identified. X-irradiation at temperatures below 200 K results in creation of a long-term temperature-independent afterglow-tunnelling luminescence (TL), with main emission bands at 300, 370 nm and 430 nm. The short wavelength TL bands are associated with the tunnelling recombination of the F type centre with the VK centre. The thermal stability of VK centre is estimated to be about 130 K.

Materials sciencelawTransition dipole momentAnalytical chemistryElectronAbsorption (electromagnetic radiation)Electron paramagnetic resonanceLuminescenceRecombinationQuantum tunnellingAfterglowlaw.invention
researchProduct

Photothermal contrast reaches single-molecule sensitivity.

2011

Materials sciencemedia_common.quotation_subjectBiophysicsAnalytical chemistryContrast (vision)MoleculeGeneral ChemistryPhotothermal therapyAbsorption (electromagnetic radiation)Sensitivity (electronics)Catalysismedia_commonAngewandte Chemie (International ed. in English)
researchProduct

Periodic unmixing of a binary metallic vapor

2005

We report on a type of surface structuring after short pulse laser ablation of a binary alloy. We observe the emergence of a concentric ring structure with changing elemental composition. The composition changes are interpreted by condensation of the ambient ablation vapor due to stress wave excitations in the ablation spot.

Materials sciencemedicine.medical_treatmentPhysics::Medical Physics: Physics [G04] [Physical chemical mathematical & earth Sciences]Binary numberElectromagnetic radiationMolecular physicsMetalOpticsPhysics::Plasma PhysicsPhysics::Atomic and Molecular Clustersmedicineskin and connective tissue diseasesSurface statesLaser ablationbusiness.industryCondensationtechnology industry and agricultureequipment and suppliesCondensed Matter PhysicsAblationElectronic Optical and Magnetic Materials: Physique [G04] [Physique chimie mathématiques & sciences de la terre]visual_artvisual_art.visual_art_mediumsense organsbusinessExcitationPhysical Review B
researchProduct

A Comparative Study of Top-Down and Bottom-Up Carbon Nanodots and Their Interaction with Mercury Ions

2021

We report a study of carbon dots produced via bottom-up and top-down routes, carried out through a multi-technique approach based on steady-state fluorescence and absorption, time-resolved fluorescence spectroscopy, Raman spectroscopy, infrared spectroscopy, and atomic force microscopy. Our study focuses on a side-to-side comparison of the fundamental structural and optical properties of the two families of fluorescent nanoparticles, and on their interaction pathways with mercury ions, which we use as a probe of surface emissive chromophores. Comparison between the two families of carbon dots, and between carbon dots subjected to different functionalization procedures, readily identifies a …

Materials scienceoptical nanomaterialsGeneral Chemical Engineeringchemistry.chemical_elementInfrared spectroscopyChromophorePhotochemistryFluorescenceArticleFluorescence spectroscopyChemistrysymbols.namesakechemistrycarbon dotssymbolsSurface modificationGeneral Materials ScienceRaman spectroscopyAbsorption (electromagnetic radiation)QD1-999CarbonsensingNanomaterials
researchProduct

Hockey-Puck micelles from oligo(p-benzamide)-b-PEG rod-coil block copolymers.

2006

Materials sciencesportsGeneral ChemistryMicelleCatalysischemistry.chemical_compoundScanning probe microscopyCrystallographyHockey puckchemistryElectromagnetic coilPEG ratiosports.equipmentCopolymerBenzamideAngewandte Chemie (International ed. in English)
researchProduct

Poor optical stability of molecular dyes when used as absorbers in water-based tissue-simulating phantoms

2019

Biomedical optical systems and models can be easily validated by the use of tissue-simulating phantoms. They can consist of water-based turbid media which often include inks (India ink and molecular dyes) as absorbers. Optical stability of commonly exploited inks under the influence of light, pH changes and the addition of TiO2 and surfactant, was studied. We found that the exposure to ultraviolet and visible light can crucially affect the absorption properties of molecular dyes. On average, absorption peaks decreased by 47.3% in 150 exposure hours. Furthermore, dilution can affect ink’s pH and by that, its decay rate under light exposure. When TiO2 was added to the phantoms, all molecular …

Materials sciencesurfactantturbid media02 engineering and technologymedicine.disease_cause01 natural sciencesIndia ink010309 opticsPulmonary surfactant0103 physical sciencesmedicinetissue-simulating phantomsmolecular dyesoptical spectroscopySpectroscopyAbsorption (electromagnetic radiation)Inkwell021001 nanoscience & nanotechnology3. Good healthDilutionoptical stabilityChemical engineering:NATURAL SCIENCES::Physics::Atomic and molecular physics [Research Subject Categories]Photocatalysis0210 nano-technologyUltravioletVisible spectrum
researchProduct

A numerical method for imaging of biological microstructures by VHF waves

2014

Imaging techniques give a fundamental support to medical diagnostics during the pathology discovery as well as for the characterization of bio-medical structures. The imaging methods involve electromagnetic waves in a frequency range that spans from some Hz to GHz and over. Most of these methods involve ionizing waves and scanning of a large human body area even if only a focused inspection is needed. In this paper, a numerical method to evaluate the shape of microstructures for application in the medical field, with a very low invasiveness for the human body, is proposed. In particular, the tooth’s root canal is considered. In fact, this is one of the hot topics in the endodontic procedure…

Mathematical optimizationMedical diagnosticAcousticsRoot canalElectromagnetic radiationSettore MAT/08 - Analisi NumericaRobustness (computer science)medicineMethod of MomentLevenberg–Marquardt methodMethod of MomentsMathematicsNon-linear modelApplied MathematicsNumerical analysisBiological microstructureNon ionizing waveInverse problemMicrostructureMagnetic fieldSettore ING-IND/31 - ElettrotecnicaComputational Mathematicsmedicine.anatomical_structureLevenberg-Marquardt methodInverse problemSettore MED/36 - Diagnostica Per Immagini E RadioterapiaJournal of Computational and Applied Mathematics
researchProduct

On the use of a meshless solver for PDEs governing electromagnetic transients

2009

In this paper some key elements of the Smoothed Particle Hydrodynamics methodology suitably reformulated for analyzing electromagnetic transients are investigated. The attention is focused on the interpolating smoothing kernel function which strongly influences the computational results. Some issues are provided by adopting the polynomial reproducing conditions. Validation tests involving Gaussian and cubic B-spline smoothing kernel functions in one and two dimensions are reported.

Mathematical optimizationPolynomialPartial differential equationApplied MathematicsB-splineNumerical analysisGaussianMeshless particle methodSmoothed Particle Hydrodynamics methodMaxwell's equationSolverSmoothed-particle hydrodynamicsSettore MAT/08 - Analisi NumericaSettore ING-IND/31 - ElettrotecnicaComputational Mathematicssymbols.namesakeElectromagnetic transientsymbolsApplied mathematicsSmoothingMathematicsApplied Mathematics and Computation
researchProduct

A low cost and easy re-configurable instrument for power quality survey

2004

In this document the development of a low cost and user friendly PC-based instrument for power quality measurement is proposed, according to IEC 61000-4-7 and standard IEC 61000-4-30. It is an easily re-configurable instrument able to measure harmonics, interharmonics and amplitude disturbances and supply unbalance. In order to verify its accuracy, the instrument has been tested according standard test procedures, by means of a built-up calibration test bench.

Measure (data warehouse)Total harmonic distortionEngineeringUser Friendlybusiness.industryElectromagnetic compatibilityDiscrete Fourier transformsReliability engineeringspectral leakageHarmonicsCalibrationElectronic engineeringPower qualityFrequency estimationbusinessVoltageProceedings of the 21st IEEE Instrumentation and Measurement Technology Conference (IEEE Cat. No.04CH37510)
researchProduct

A full wave three dimensional meshless approach for electromagnetic transients

2010

Meshfree methodElectromagnetic transients
researchProduct